BIM Services in Orange County, CA
ScanM2 provides BIM services in Orange County, CA for architects, MEP and fire protection engineers, contractors and building owners. We build Revit models of existing buildings from our own laser scans, from your point cloud or from old drawings, then add what your project needs: MEP and fire sprinkler modeling, custom families, clash checks and sheets. Models built from our scans follow the typical building scan accuracy of ±2–3 mm.
Contact Us Now for a Free Consultation!
There is no ScanM2 office in Orange County. Our crew travels to sites across the county for scanning, and our own team does the modeling. For a model of the existing building only, without design-stage work, see our page on Scan to BIM in California.
Which BIM Service Do You Need?
| Service | What you receive | When it is worth ordering |
|---|---|---|
| Existing-conditions model | Architecture and structure of the building as it stands | Any remodel, addition or tenant improvement designed in Revit |
| MEP modeling | Ducts, pipes, equipment and trays in the work zones | New systems must connect to or pass existing ones |
| Fire sprinkler modeling | Visible mains, branch lines and heads in the model | The fire protection designer needs the existing layout |
| Clash detection | Clash report between your new design and the existing model | Tight ceilings, crowded plant rooms, new equipment |
| Revit families | Parametric families of equipment, fixtures or custom elements | Repeated items that are not in your library |
| Model from drawings | PDF to Revit or CAD to BIM | Layout studies where measured accuracy is not critical |
| Sheets from the model | Plans, sections and elevations set up as Revit sheets | Your team adds the design and annotations |
You can order one row or combine several. A common combination for an office suite is an existing-conditions model, MEP in the ceiling zone and a clash check once the new layout is drawn.
What the Model Should Hold for Orange County Buildings
Offices and medical suites in business parks
In business parks across Irvine, Costa Mesa, Santa Ana and Tustin, suites change between office, medical and lab tenants. Most design changes happen in the ceiling: ducts, diffusers, sprinkler heads, lights and the space up to the structure. Model the ceiling zone of the affected area with visible MEP and the roof equipment above it. Leave untouched suites as walls and doors only. Our MEP BIM services page covers the disciplines.
Tilt-up warehouses and industrial buildings
For concrete tilt-up shells and older steel buildings, from North County to the industrial areas of Irvine and Tustin, the model for a new tenant should show clear heights at several points, roof framing, sprinkler mains, dock doors, columns and existing racking. Racking height and layout matter to the fire protection review: the Orange County Fire Authority lists high-piled storage among the hazardous operations it reviews, separately from sprinkler plans.
Hotels and restaurants
Guest rooms that look the same rarely are. We model typical rooms in full and check others against the scan for differences. Kitchens need hoods, equipment, floor drains and connections as separate elements. See BIM services for hotels.
Custom homes on the coast
For a remodel or addition designed in Revit, the model should include all floor levels, roof forms, decks, stairs and the lot slope near the house. Fine trim can stay in the point cloud as a reference instead of being modeled.
Fire Plan Review in Orange County and the Model
The Orange County Fire Authority serves 23 cities and all unincorporated areas of the county, including Irvine, Santa Ana, Tustin, Garden Grove, Mission Viejo and San Clemente. Its planning and development services review plans in six categories, among them architectural plans, hazardous operations and materials, fire sprinklers and fire alarms. Cities outside that list handle fire review through their own arrangements, so confirm the reviewer for your address first.
How the model helps:
- Visible sprinkler mains, branch lines and heads give the fire protection designer the existing layout to work from.
- Clear heights, roof framing and racking positions are measured, not assumed.
- Walls, doors and rooms in the model can feed the architect’s exit and occupancy plans.
What the model does not do: it is not a sprinkler design, hydraulic calculation or code analysis. Those stay with your licensed fire protection engineer and architect. We do not file plans, stamp drawings or promise approval.
What We Agree On Before Modeling
Most problems with a delivered model come from a setup nobody discussed. We confirm these points in writing before work starts.
| Item | What we ask | Why it matters |
|---|---|---|
| Revit version | The version your team uses | Revit files cannot be opened in older versions |
| Template | Your template file or ours | Keeps view names, line styles and browser order consistent |
| Coordinates | Local, project grid, or surveyor’s points in CCS83 Zone VI | The model lines up with civil and site files |
| Levels and grids | Names and reference heights | Avoids renaming every view later |
| Phases | Existing, demolition, new | The existing model drops straight into a remodel |
| Worksets | Split by discipline or by building | Several people can work in the model at once |
| Level of detail | Per category, not one number for everything | Detail goes where the design needs it |
| Exports | RVT, .ifc, NWC, DWG | Each consultant gets a file they can open |
For choosing detail by category, see our article on BIM level of detail.
Clash Checks Against What Already Exists
Clash detection is usually run between new design models. In a remodel, the bigger risk is the existing building: a beam lower than the drawings show, a duct no one recorded or a pipe in the way of a new opening. We run your new design against the existing model and deliver a clash report grouped by location and severity. Your designers decide how to resolve each item.
What a Model of an Existing Building Cannot Show
A model built from a laser scan includes only what was visible. Pipes inside walls, framing behind finishes and anything above closed ceilings are not in it unless tiles are opened or you provide drawings we can trace. Elements traced from old drawings are marked so your team knows they were not measured. Material, fire rating or structural capacity cannot be read from a scan.
Sample Scope You Can Adapt
- Building: single-story tilt-up warehouse with a two-story office area, about 60,000 sq ft
- Model: walls, columns, roof framing, dock doors, mezzanine, office interiors
- MEP: sprinkler mains and branch lines in the warehouse; ducts and diffusers in the office
- Also show: existing racking footprint and height, clear heights on a grid
- Setup: client template, Revit version agreed, phases existing and new
- Deliverables: RVT, .ifc, NWC, registered point cloud in E57
This is an example, not one of our projects.
Need the existing building first? See Scan to BIM in Orange County and 3D scanning in Orange County.
FAQ
What do your BIM services in Orange County include?
Can you model existing fire sprinklers?
Will the Orange County Fire Authority accept your model?
Can you work in our Revit template and version?
Can the model be placed in survey coordinates?
Which level of detail should I order?
How accurate is the model?
Do you have an office in Orange County?
What to Send Us
- Address, building type, floors and approximate area
- The project: tenant improvement, addition, equipment change or records
- Disciplines and areas to model
- Your Revit version, template and any BIM standard
- Existing drawings or point clouds
- Access rules, site contact and areas that cannot be entered
For models statewide, see BIM services in California; for Los Angeles County, see BIM services in Los Angeles. Drawings without a model are covered on our as-built services in Orange County page.
Send us the address and the task, and we will suggest which BIM services to order.