Scan to BIM Scope of Work: What to Include in Your RFP (with Template)
A scan to BIM scope of work tells the scanning and modeling team exactly what to capture, what to model, how detailed and how accurate the model must be, and what files you expect at the end. When the scope is vague, two bidders can price two different projects, and the model you receive may not fit the job it was meant for. When the scope is clear, proposals are comparable and the model arrives ready to use.
This guide goes through the sections a good scan to BIM RFP should contain, with a table of examples and a template you can copy into your own request. If you are an architect looking for the working sequence with a scanning partner, see our scan to BIM checklist for architects. For the service itself, visit our scan to BIM services page.
1. Purpose and Intended Use of the Model
Start with why you need the model. The intended use drives every other decision in the scope: what to scan, which disciplines to model, how much detail to include and which tolerance makes sense.
Typical uses include:
- design of a renovation, fit-out or addition;
- MEP retrofit and coordination with new systems;
- space planning and area measurement;
- facility management and asset records;
- documentation of a historic building;
- permit drawings based on verified existing conditions.
One sentence is often enough: “The model will be used by the architect and MEP engineer to design a full interior renovation of levels 2 to 5.” If the model will serve more than one purpose, list them in order of priority. Our point cloud to BIM services for existing buildings page shows how the same scan can support several of these uses.
2. Project Boundaries and Areas
Describe the physical limits of the work so nobody has to guess. Include:
- the address and building name, and the approximate gross area in square feet;
- the levels in scope, including basements, mezzanines and roof;
- interior areas in and out of scope: tenant spaces, plant rooms, shafts, ceiling voids, locked rooms;
- the exterior: which facades, the roof, canopies, parking structures;
- site elements: paving, curbs, retaining walls, surface signs of underground utilities such as manholes and valve boxes.
Marked-up floor plans or a site plan with the scope shaded are the clearest way to show this. If above-ceiling spaces must be scanned, say whether ceiling tiles can be lifted and who will do it.
3. Disciplines: What to Model and What Not to Model
List each discipline and what it includes:
- Architectural: walls, doors, windows, floors, ceilings, stairs, ramps, built-in casework, roof.
- Structural: columns, beams, slabs, bracing, foundations where visible.
- MEP: ductwork, piping, cable trays, equipment, fixtures, fire protection.
Equally important is what should stay out of the model. Loose furniture, small fittings, conduit below a certain size or decorative details may not be needed for your use and only add modeling effort. Set a minimum size for pipes and ducts to be modeled, and state what happens to elements that are only partly visible in the scan. Our article on Revit modeling from point cloud: what should be modeled and what shouldn’t covers these choices in detail.
4. Level of Detail by Area
LOD does not have to be the same everywhere. A plant room for an MEP retrofit may need LOD 300 or higher for equipment and piping, while office floors only need walls, doors and ceilings at LOD 200. Write the LOD per discipline and per area, for example in a short matrix.
Name the LOD standard you refer to, such as the BIMForum LOD Specification, so both sides read the numbers the same way. For a plain-language explanation of each level, see BIM LOD levels explained.
5. Accuracy Requirements
Do not write “high accuracy” or “as accurate as possible”. State the tolerance you need: how far the model may deviate from the point cloud, and whether the requirement differs by discipline or area. If you work to a standard such as the USIBD Level of Accuracy specification, name the level for measured data and for modeled data.
Keep scan accuracy and model tolerance apart. With FARO laser scanners, the registered point cloud typically has an accuracy of ±2–3 mm. The model tolerance is a separate figure that depends on the intended use and the LOD. What affects model accuracy and how it is checked is the subject of our guide to factors affecting scan to BIM accuracy.
6. Registration and Survey Control
Registration joins individual scans into one point cloud. Your scope should say how you want it controlled and reported:
- whether the cloud must be tied to existing survey control or a project benchmark;
- who provides the control points, if any;
- what registration report you expect, for example scan overlap and alignment statistics from the registration software.
If you only need a model in a local coordinate system, say so; it keeps the work simpler. More on the process in how point cloud registration works.
7. Standards: Revit Version, Template, Naming and Coordinates
Small setup details cause most rework at handover. Specify:
- the Revit version the model must be delivered in;
- your Revit template, or that the modeler may use their own;
- file, view, sheet and family naming rules, or a reference to your BIM standard;
- worksets, if your team uses them;
- the coordinate system: local, project base point at a given grid intersection, or a state plane coordinate system;
- units and level names.
If you have a BIM execution plan, attach it and refer to it instead of repeating it in the RFP.
8. Deliverables
List every file you expect, with its format:
- Revit model (.rvt), one file or split by discipline or building;
- .ifc export for teams on other platforms; our IFC file format guide explains what to expect from it;
- registered point cloud in the format you can open, such as .rcp/.rcs or .e57;
- sheets: plans, sections, elevations, reflected ceiling plans, as PDF and/or .dwg;
- 360° panoramic images from the scan positions, if useful for your team.
Say how files should be delivered: a shared folder, your common data environment or another platform.
9. Site Access and Building Schedule
The scanning team needs to know the conditions on site before planning the work:
- whether the building is occupied and which areas are sensitive;
- working hours, after-hours or weekend access;
- escort, badge, safety training and PPE requirements;
- roof, ceiling and plant room access, including lifts or ladders;
- parking and equipment storage.
We travel to sites in any US state. If you already have a point cloud, include its format and registration report; the modeling can then start from your data without a site visit.
10. Revisions, Acceptance and QC
Describe how the model will be reviewed and accepted:
- how many review rounds are included, and what counts as a revision versus a change in scope;
- how comments will be submitted: marked-up PDF, BCF issues or a spreadsheet;
- what QC you expect from the modeler, for example a model-to-cloud deviation check or a review of each level against the point cloud;
- who on your side signs off the deliverables.
Clear acceptance criteria tied to the tolerance from section 5 make the review faster for both sides.
11. What to Attach to the Request
The more context you send, the more accurate the proposals. Useful attachments:
- existing drawings, even if outdated;
- marked-up plans showing the scope;
- photos of the building and of difficult areas;
- your Revit template and BIM standard or BEP;
- any existing point cloud with its registration report;
- the LOD matrix by area and discipline.
Scan to BIM RFP Sections at a Glance
| Section | What to specify | Example |
|---|---|---|
| Purpose | Intended use of the model, in order of priority | Interior renovation design, then facility management |
| Boundaries | Levels, areas, facades, roof, site | Levels B1 to 5, roof, north and east facades, parking excluded |
| Disciplines | What to model and what to leave out | Architecture and structure; MEP in plant rooms only; no loose furniture |
| LOD | Level per discipline and per area | LOD 200 offices, LOD 300 plant room and risers |
| Accuracy | Tolerance for the model, standard referenced | Model within the tolerance you set; point cloud at ±2–3 mm |
| Registration | Control, coordinate tie-in, report | Tied to the owner’s benchmark, registration report included |
| Standards | Revit version, template, naming, coordinates | Revit version per BEP, client template, state plane coordinates |
| Deliverables | Files and formats | .rvt, .ifc, .e57 point cloud, PDF sheets |
| Site access | Occupancy, hours, safety, escorts | Occupied office, after-hours access, badge and escort required |
| Revisions and QC | Review rounds, comment format, acceptance | Two review rounds, BCF comments, deviation check before sign-off |
| Attachments | Documents sent with the request | Old drawings, marked-up plans, photos, BEP |
Scan to BIM Scope of Work Template
Copy this list into your RFP and fill in each line. Delete what does not apply.
- Project name and address:
- Building type and approximate area (sq ft):
- Intended use of the model:
- Levels in scope:
- Interior areas included / excluded:
- Exterior: facades, roof, canopies:
- Site elements:
- Above-ceiling scanning: yes / no; who lifts ceiling tiles:
- Disciplines: architectural / structural / MEP / fire protection:
- Elements to exclude from the model:
- Minimum pipe and duct size to model:
- LOD by discipline and area (standard referenced):
- Required model tolerance (standard referenced):
- Survey control and coordinate system:
- Registration report required: yes / no:
- Revit version:
- Template and naming standard (attached / modeler’s own):
- Deliverables and formats: .rvt / .ifc / point cloud format / sheets / panoramas:
- Delivery method:
- Occupancy and working hours:
- Access, escort and safety requirements:
- Review rounds and comment format:
- QC and acceptance criteria:
- Contact person on site and for model review:
- Attachments: drawings / marked-up plans / photos / BEP / existing point cloud:
FAQ
What is a scan to BIM scope of work?
What is the difference between an SOW and an RFP?
Do I need to specify LOD for every area?
What accuracy should I ask for?
Does the scope of work affect the price?
Send a Clear Scope, Get a Model That Fits
A well-written scan to BIM scope of work answers the questions a provider would otherwise have to guess: why the model is needed, where the boundaries are, what to model and at what level of detail, which tolerance applies, how the files should be set up and how the result will be accepted. Use the template above as a starting point, attach your drawings and standards, and you will get proposals you can compare and a model that fits your project. ScanM2 scans with FARO laser scanners, models in Revit for architecture, structure and MEP, and can also work from your existing point clouds. Learn more about our scan to BIM services, or send us your scope to discuss the project.